Long dry times and the Flow Sense codes
Start here, because it is the top LG dryer call. LG builds a duct check into its vented dryers. It is called Flow Sense.
A d80 code means the duct is about 80 percent blocked. A d90 or d95 code means it is worse. LG says not to run the dryer with a badly blocked exhaust until the duct is cleaned.
The dryer is not broken when it shows these codes. The vent in the wall is. Still, a blocked duct hurts the dryer over time. Heat backs up. The thermal fuse blows. Then you have no heat at all. We check the duct, the hose behind the unit and the flap outside.
No heat on an electric LG dryer
When the drum turns and the air is cold, we test these parts.
- Heating element, which can break or short to its case.
- Thermal fuse, a one time part that opens when heat backs up.
- High limit thermostat on the heater box.
- The 240 volt supply. One tripped breaker leg lets the drum spin with no heat.
No heat on a gas LG dryer
Gas models light a burner with an igniter. The igniter glows, then a valve opens. A cracked igniter will not glow. Weak valve coils let the flame start and then die. A flame sensor can fail as well. We watch the burner through a full cycle to see which part drops out.
Heat pump and WashTower dryers
LG also makes ventless dryers. Some WashTower units use a Dual Inverter HeatPump dryer. These reuse their air in a closed loop and need no duct.
They fail in other ways. Lint builds on the inner coil. The water they pull from clothes must drain away. A blocked drain path or dirty filter makes dry times stretch. There is no duct to blame, so the fix is inside the machine.
Thumps, squeals and a drum that stops
Noise comes from the parts that hold the drum. Rollers wear flat and thump. The idler pulley squeals. A belt that snaps leaves the motor running with a still drum. We open the cabinet and replace worn parts as a set. It saves a second trip later.
Damp clothes at the end of a sensor cycle can be a sensor issue. LG Sensor Dry feels for moisture with metal bars inside the drum. Film from dryer sheets coats them. A wipe with rubbing alcohol often helps.
Clean the lint filter every load. If water beads on the screen, scrub it with dish soap. Slide the dryer forward and look for a crushed hose. Go outside and see that the vent flap opens. On a steam model, check the water line to the dryer.
Scheduling and cost
A home visit to find the fault is $79. A stacked or double unit is $119. Choose to have us fix it and that fee is dropped. You will know the full price first, parts and labor included. Dryer bookings begin at 6 AM and run to 9 PM, with no days off. Same-day slots are there for most calls. Your dryer tech carries insurance, holds a license and has been background checked. Many common parts ride on the truck. The job is backed by a 30-day repair warranty. We are independent and not tied to LG.
Is the dryer worth it
Yes, in most cases. A dryer is a drum, a motor, a heater and a few sensors. Fuses, elements, igniters, belts and rollers are all low cost next to a new LG. A heat pump unit with a sealed system fault is the rare case where we talk about a new one.
We serve D.C. through our Washington D.C. appliance repair page. See dryer repair for more, or the LG appliance repair page for the brand. The machine next to it is covered under LG washer repair. We run a timed load before leaving, so you know the dry time is back to normal.